AcornSearch - Acorn and RISC OS information searching
RISC OS Search
containing
"Nutty quip goes here!"
Home  |  About  |  Filebase Archive  |  StrongHelp Manuals  |  Newsgroups  |  Module Database
Bit     Meaning when set

0     'OK' box
1     'Cancel' box
2     Highlight Cancel (or OK if no Cancel box)
3     Don't do 'Press space or click mouse to continue'
4     Don't prefix title with 'Error from '
5     Return immediately with R1=0 and box open
6     Simulate iconclick in box according to bits 0+1
7     Don't beep
8     Use categories
9-11     Category
12-23     Reserved. Must be 0
24-27     Number to return for "Continue" of "may have gone wrong" (4.00+)
28-31     Number to return for "Quit" of "may have gone wrong" (4.00+)
Wimp_ReportError categories
#     Meaning

1     Informational.
2     Warning.
3     Program (ie non-desktop) message (stop).
4     Question; usually used with the button string.
5     User icon 1 (ie undefined)
6     User icon 2 (ie undefined)
7     Program again (do not use)

These define the type of error under RO3.50 and display the type of the error. Bit 8 must be set.